- Conversion of a UHT system: process, piping, flow measurement, optimisation of system part sterilisation tank, valves, pumps, software changes (adjustments, optimisations)
- Connection of the UHT system to CIP cleaning using CIPAL nodes
- Conversion of the homogeniser and optimisation
- Electrical and mechanical installation; start-up with tests of components, water and sterilisation; product support; documentation and measuring technology
Result: The reduction of costs and extension system life through reduced wear to system parts
- The initial planning of a desert plant and optimisation of the thermal systems for the product and yield
- Determination of needs in the entire energy sector with consideration of the use of waste heat in CHPs.